DECKMA 1

OMD- 2008 Series

5 ppm + 15 ppm Bilge Alarm according to IMO Resolution MEPC.107 (49)

 

pdf iconOMD_2008_Series_Instruction_Manual_R06_20221109.pdf

 

Property
Value
Range (measurement & indication)
0 - 30 ppm, Trend up to 50ppm
Range (IMO specification)
0 - 15 ppm (according IMO regulations)
Accuracy
better than IMO MEPC.107(49)
Electrical power supply
24V - 240V, AC or DC, Automatic Voltage Selection
Electrical power consumption
< 10 VA
Sample
Oily water from separator outlet, 0,1 - 4 l/min
Sample temperature range
+1°C  to +65°C
Sample connections
R 1/4" Female
Alarm 1 & 2 Set Points
1 - 15ppm (independently adjustable)
Alarm 1 operating delay for annunciation
1 - 540 sec
Alarm 2 operating delay for control
1 - 10 sec
Alarm contacts
2 independently adjustable switchover contacts
Alarm contact operation mode
De-energized in Alarm State
Alarm contact ratings
3A, 240V each
Alarm output
0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150Ω
Display
Graphic Display
Ambient temperature
+1°C to +55°C
Class of protection
IP 65
Dimension
360 x 240 x 100 mm (WxHxD)
Weight
5,4 kgs

 


Print